KC-P30 x-series System overview
Configuration manual V4.09
14
© KEBA
2.2.2 Direct connection of master and slave
A single slave charging station can be connected directly to the master
charging station via LAN.
Fig.2-3: Direct connection of master and slave
1 ... P30 x-series (master) 2 ... P20/P30 c-series (slave)
In this case, the master charging station must be configured as a DHCP
server. The IP address is then assigned to the slave charging station by the
master charging station.
2.2.3 Connection via router or switch
If there are multiple slave charging stations, these must be connected to the
master charging station via a router or switch. The connection of the charg-
ing station to the router/switch is made via LAN
Fig.2-4: Connection via router or switch
1 ... Router/Switch 2 ... P30 x-series (master)
3 ... P20/P30 c-series (slave)