KC-P30 x-series Configuration
Configuration manual V4.09
20
© KEBA
Information
By deleting all Connect2ConnectorSerial entries, the charging station au-
tomatically searches for other charging stations in the charging network. As
many charging stations are searched as specified under AmountConnec-
tors.
Adapt configuration (optional)
If necessary, the configuration can be adapted manually. Each of the listed
settings can be adapted by editing the value to the right of the equal sign "=".
Example of a possible adaptation of the configuration
Initial configuration Adapted configuration
AuthorizationEnabled=true AuthorizationEnabled=false
Information
Invalid settings will not be applied.
3.4.4 Import configuration
To load the configuration into another P30 x-series, the USB stick must be
plugged in to the desired charging station. The configuration will be imported
automatically and adopted after a restart.