4.1.5 Configuration
The configuration of the charging station is carried out in this area.
Information
The DIP switch settings are independent of the web interface configuration
and cannot be overwritten by software.
The area offers the following options:
Operating Mode
Device
Charging Network Parameters
Chargepoint Parameters
Network Connection
Certificates
WLAN access point
Proxy
OCPP
External TCP Meter
Display Text
Information
The settings made are only applied after the "Apply" button has been
pressed.
Operating Mode
Here you can determine whether the charging station is operated as a single
charging station or as a master charging station in a charging network.
The number of slaves must be entered for a charging network. In addition,
all attached slave charging stations must be entered with their respective se-
rial numbers. Otherwise, the slave charging station will not be recognized by
the master charging station in the network. The serial number is printed on
the rating plate of the slave charging station.
Both the master charging station and all attached slave charging stations
can be enabled ("available") or disabled ("out of service") individually. If the
charging station is disabled during a charging process, the charging process
will be stopped. When the charging station is disabled, the LED bar slowly
flashes orange and the display shows that the charging station is out of op-
eration.