KC-P30 x-series Functions
Configuration manual V4.09
35
© KEBA
Port Protocol Definition Description
Custom
(1025 -
65535)
TCP
Can be reached externally
(incoming)
OCPP Charge Point Service: This
service is related to the OCPP
backend.
The port can be freely selected
or it is specified by the OCPP
backend. However, the port
may only be located in the
range from 1025 to 65535.
The selected port must be
configured on the charging
station.
Custom TCP
Access to external (outgo-
ing)
Port at which the OCPP backend
can be reached.
123 UDP Incoming and outgoing
Port for the time server of the
charging station.
Supported messages
The following table provides an overview of the supported messages.
Message OCPP 1.5 OCPP 1.6
Authorize x x
BootNotification x x
ChangeAvailability x x
ChangeConfiguration x x
ClearCache x x
DataTransfer x x
GetConfiguration x x
Heartbeat x x
MeterValues x x
RemoteStartTransaction x x
RemoteStopTransaction x x
Reset x x
StartTransaction x x
StatusNotification x x
StopTransaction x x
UnlockConnector x x
GetDiagnostics x x
DiagnosticsStatusNotification x x
FirmwareStatusNotification x x
UpdateFirmware x x
GetLocalListVersion x x
SendLocalList x x
CancelReservation x