Printed in U.S.A. 440 04 4201 03 July 2012
SERVICE AND TECHNICAL
SUPPORT MANUAL
Modulating, Variable Speed Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
(
F/G
)
9MAC
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
SELECT SETUP SWITCH POSITIONS 4.....................
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 5......................................
ADJUSTMENTS 5.........................................
ADJUST TEMPERATURE RISE 8............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 9..............
ADJUST COOLING AIRFLOW 9.............................
ADJUST CONTINUOUS FAN AIRFLOW 9....................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 12.............................
CHECKLIST 12.............................................
COOLING AND HEATING AIR DELIVERY 17...................
SERVICE AND MAINTENANCE PROCEDURES 21.............
ELECTRICAL CONTROLS AND WIRING 21...................
CLEANING AND/OR REPLACING AIR FILTER 23..............
CLEANING BURNERS AND FLAME SENSOR 25...............
SERVICING HOT SURFACE IGNITER 26......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 27....
CLEANING CONDENSATE DRAIN AND TRAP 27..............
WINTERIZATION 28........................................
SERVICE LABEL 29.........................................
TROUBLESHOOTING CHART FLOW CHART 31.............
TROUBLESHOOTING GUIDE FLOW CHART 32..............
SEQUENCE OF OPERATION 34.............................
PARTS REPLACEMENT INFORMATION GUIDE 38.............
PRODUCT NOMENCLATURE 39.............................
MODELS
(F/G)9MAC0601714A
(F/G)9MAC0602120A
(F/G)9MAC0801714A
(F/G)9MAC0802120A
(F/G)9MAC1002122A
(F/G)9MAC1202422A
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
Question and Answer IconNeed help?

Do you have a question about the KeepRite G9MAC0801714A and is the answer not in the manual?

Summary

Safety Labeling and Signal Words

Safety Considerations

General Safety Warnings

Covers crucial safety warnings regarding installation, service, and hazards like shock, fire, and CO.

Start-Up, Adjustment, and Safety Check

General Start-Up Requirements

Outlines essential prerequisites for furnace start-up, including power, grounding, and wiring.

Setup Switch Configuration

Details how to configure furnace setup switches (SW1, SW2, SW3, SW4) for specific applications and airflows.

Gas Line and Pressure Adjustments

Manifold Pressure Adjustment

Guidance on adjusting manifold pressure for proper gas input rate, considering altitude and gas value.

Inlet and Manifold Pressure Checks

Check Inlet Gas Pressure

Steps to verify the incoming gas pressure is within the required operating range for the furnace.

Adjust Manifold Pressure - Maximum Heat

Procedure for setting the manifold pressure for maximum heat output to achieve the correct input rate.

Manifold Pressure and Meter Clocking

Adjust Manifold Pressure - Minimum Heat

Steps for setting the manifold pressure for minimum heat output, ensuring correct input rate.

Temperature Rise and Airflow Settings

Adjust Temperature Rise

How to measure and adjust air temperature rise to ensure optimal furnace operation and prevent overheating.

Adjust Cooling Airflow Settings

How to configure setup switches for desired high-speed and low-speed cooling airflows.

Blower Speed and Airflow Adjustments

Adjust Cooling Airflow - High-Speed and Low-Speed Cooling

Configuration steps for setting cooling airflow based on tonnage using setup switches.

Safety Control Checks

Burner and Flame Sensor Servicing

Hot Surface Igniter Servicing

Drainage System Maintenance

Furnace Winterization Procedures

Winterizing the Furnace

Steps to prepare the furnace for cold weather or extended shutdowns to prevent freeze damage.

Troubleshooting Guide - Flow Chart

Initial Status Check

Steps to check the furnace control's status LED and basic power supply before proceeding with detailed diagnostics.

Sequence of Operation

Heating and Cooling Modes

KeepRite G9MAC0801714A Specifications