Typical LIMIT UNIT
1) THD (@70Hz with 20KHz Filter)
Output 100W 0.08 0.35 %
Output 28V,No load 0.8 1.0 %
2) Input sensitivity (@100Hz with 20KHz Filter)
Output 100W 580 +/-10% mVrms
Output 160W 1.8 +/-15% Vrms
3) S/N (@70Hz Input, A-Weight)
Output 40W 95 85 dB
Output 160W 100 95 dB
4) Filter (@70Hz 10mV Input, Output ref 0dB)
High Pass Filter, -6dB Point 30 +/-10% Hz
Low Pass Filter, -6dB Point 360 +/-10% Hz
5) Filter Roll-off (Relative to -6dB Point)
High Pass Filter Roll-off -12 +/-2 dB
Low Pass Filter Roll-off -28 +/-4 dB
6) Bass Boost (@40Hz 10mV Input, Bass Boost set to 0dB, Output ref 0dB)
Bass Boost Switch set to +6dB +6.5 +/-1 dB
Bass Boost Switch set to +12dB +13.5 +/-1 dB
7) Phase Adjustable (@100Hz Output 10V ref 0 degree)
Phase Switch set to 0 degree 0 0 degree
Phase Switch set to 180 degree 180 180 degree
8) Hum & Noise (Bass Boost Switch set to +12dB, Input with 1K ohm)
Output with 20KHz Filter <3 5 mVrms
9) Current Consumption < 10 second
JAP 100V @Output 160W 3 3.5 A
@IDLE 0.15 0.20 A
US 115V @Output 160W 2.8 3.2 A
@IDLE 0.15 0.20 A
EU/UK 230V @Output 160W 1.5 1.8 A
@IDLE 0.10 0.15 A
AUST 240V @Output 160W 1.5 1.8 A
@IDLE 0.10 0.15 A