12-52 Return to Section Topics 2600S-901-01 Rev. C / January 2008
Section 12: Instrument Control Library Series 2600 System SourceMeter® Instruments Reference Manual
smuX.cal.restore
X = SMU channel (a or b)
Function Loads a stored set of calibration constants.
Usage There are two ways to use this function:
smuX.cal.restore()
smuX.cal.restore(calset)
calset Calibration set to be loaded.
Set calset to one of the following values:
smuX.CALSET_NOMINAL A set of calibration constants that are
uncalibrated but set to nominal values to
allow rudimentary functioning of the
instrument.
smuX.CALSET_FACTORY The calibration constants when the instrument
left the factory.
smuX.CALSET_DEFAULT The normal calibration set.
smuX.CALSET_PREVIOUS The calibration set that was used before the
last
default set was overwritten.
If calset is not specified, smuX.CALSET_DEFAULT will be used.
Remarks • This function will overwrite the current set of calibration constants from non-volatile
memory.
• This function will be disabled until a successful call to smuX.cal.unlock is
made.
Details See Section 16 "Calibration".
Example Restores factory calibration for SMU A:
smua.cal.restore(smua.CALSET_FACTORY)
smuX.cal.save
X = SMU channel (a or b)
Function Stores the calibration constants in non-volatile memory.
Usage smuX.cal.save()
Remarks • This function will store the current set of calibration constants in non-volatile memory. The
previous calibration constants (from the default calibration set) will be copied to the
previous calibration set (smuX.CALSET_PREVIOUS) prior to overwriting the default
calibration set.
• This function will be disabled until a successful call to smuX.cal.unlock is
made.
For models 2601, 2602, 2611 and 2612: If any of the calibration constants have
been changed, this function will be disabled unless both the calibration date and the
calibration due date have been assigned new values. For models 2635 and 2636: If any
of the calibration constants have been changed, this function will be disabled, unless the
calibration adjust date has been set.
Details See Section 16 "Calibration".
Also see smuX.cal.date, smuX.cal.due, smuX.cal.restore
Example Stores calibration constants for SMU A in non-volatile memory:
smua.cal.save()
smuX.cal.state
X = SMU channel (a or b)
Attribute Calibration state.
Usage calstate = smuX.cal.state

Table of Contents

Other manuals for Keithley 2635

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2635 and is the answer not in the manual?

Keithley 2635 Specifications

General IconGeneral
BrandKeithley
Model2635
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals