4. Operation Elements and Function
ON/OFF – switch
(Motor protection switch)
Monitoring light for operation mode
The lter unit has been equipped with an automatic cleaning system, which controls the air volume and starts a cleaning cycle
of the lter cartridges.
5. Maintenance
5.1 Emptying of the dust container
The dust container has to be emptied regularly. The time period between two emptyings
is dependent on the kind and the volume of the captured dusts.
• Please avoid any contact with the dust. Use the disposable dust protection mask, the disposable protection gloves,
the dust bin liner (for dust collection container) and the lacing cord.
• Ensure the unit is not in operation when removing or replacing the dust collection container.
Warning:
Your health can be affected if you inhale the particles in the welding dust, in particular the dusts generated during processing of
galvanised steel are very harmful. Human skin can be irritated by the particles in the welding smoke (in particular for people who are
sensitive against these harmful substances).
• Switch the unit off by using the motor protection switch
• Disconnect the unit from the power supply
• Wait a few minutes until the raised particles in the dust collecting bin are settled
• Loosen the toggle fasteners and open the maintenance door carefully in order to prevent the dust from raising
• Draw the dust collection bin outside the lter housing
• Carefully pull the disposal bag without rising dust over the bin and remove it from the unit
• Empty the dust collecting bin
• Close the disposal bag with a cable tie
• If the dust collecting bin is damaged replace it and dispose it according to the legal regulations.
• Replace the empty bin or place a new one into the lter unit
• Close the maintenance door and secure it with toggle tip fasteners
• Connect the unit to the power supply
• Switch the unit on by using the motor protection switch
• The unit is ready for operation agai
The dusts have to be stored and disposed according to the law for disposal and secured against any
danger of polluting the environment.
Drehrichtung
Betrieb
0/l
Von-Siemens-Str. 20 · D-48691 Vreden
Tel: +49(0) 2564/ 68 - 0 · Fax: +49(0)25 64 / 68-120
mail@kemper.eu · www.kemper.eu
Filter-Cell XL
Druckluftversorgung!
Benötigt wird saubere, trockene und ölfreie Druckluft
mit einem Druck von 4 - 6 bar.
Elektriker!
Falsche Drehrichtung des Ventilators hat eine um 40 % geringere
Saugleistung zur Folge. Bei falscher Drehrichtung durch Wechsel
von 2 Phasen Drehrichtung korrigieren!
maintenance door
lter cartridge
dust collection container
motor protection switch
toggle fasteners