4
5.2 Drain of condensate out of the compressed air vessel
Condensate will be collected inside the compressed air vessel. This condensate should be drained during emptying of the dust collection
container. The drain valve is located on the back side of the lter unit. You can put a suitable container below the drain valve and open the
valve. Close the valve after all moisture has been drained and only air is puring out of the valve.
6.TechnicalSpecication
7. Spare parts list
8. Inspection
The inspection of the lter unit has to be undertaken according to TRGS 560 chapter 5, paragraph 9. You have to record the results of the
inspections in an inspect and test log book. This log book has to be handed out to the inspection authority if this is required.
The user does not have to carry out further inspections. The annual main service or any repairs have to be undertaken by KEMPER service
engineers. Please have a look at the test badge on the unit for getting the next service date. Maintenance work may only be undertaken in a
well air circulated and suitable place to ensure that no people will be affected by any released dust. The engineer should wear protection
equipment as protective gloves, disposal gloves etc. to avoid any contact with hazardous substances. The working station has to be cleaned
after carrying out the maintenance work.
Item Description Part No.
1 KemTex
®
ePTFE-Membran-Filterpatrone
(Der Einbau darf nur durch den KEMPER - Service erfolgen)
109 0300
Capacity: 1.000 m³/h
Max. pressure: 2.900 Pa
Effective lter surface: 10 m²
Power supply: see type plate
Motor performance: 1,5 kW
Amperage: see type plate
Operation period: 100 %
Voltage: 24 V
Dimensions (W x D x H): 655 x 655 x 1.460 mm
Weight: 135 kg
Allowed surrounding temperature: - 10 °C up to + 35 °C
Noise level at a distance of 1 m
at maximum air volume
69 dB (A) measured on an open air
test side according to DIN EN ISO 3744
Daily inspections
Type of inspection Troubleshooting / Measurements
• heck the lling level of the dust extraction container.
• Drain the condensate from the compressed air vessel.
• Check if the connection cable and the CEE plug are not
damaged.
• Check the sense of rotation of the fan if the position of
the unit has been changed.
• Check if the lter material of the lter cartridge is not
damaged.
• See chapter „Emptying of the dust collection container“.
• See chapter „Drain of condensate from
the compressed air vessel.
• Visual inspection, it might be necessary to get the connection
cable or the CEE plug replaced by an authorized electrician.
• See „Placing into operation“.
• Check at the blow out grid on the back side of the lter unit if smoke is
released or dust is layered on the grid during operation of the unit.
This might be an indication of a lter damage. Particles will only be held
back insufcient. Please do not use the lter unit in this case as the
polluted air can get into the working environment of the user and affect
the health of people near the machine. Please contact KEMPER service
department and ask for a service and repair of the lter unit.