2.6 Panel MS 200 and MS 300 setup parameters
Normal MIG welding Setup -parameters
Name of parameter
Name on
display
Parameter
values
Factory
setting
Description
Pre Gas Time
PrG 0.0 – 9.9 s 0,0 s Pre gas time in seconds
Post Gas Time
PoG 0.0 – 9.9 s Aut Post gas time in seconds or automatically
according to welding current (Aut)
Creep Start
Cr OFF, on OFF Switch creep start on or o.
Creep Start Level
CrE 10 – 170% 50% Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start
Start Power
StA -9 ... +9 0 Strength of start pulse
Post Current Time
PoC -9 ... +9 0 Post current
Arc Voltage
Ard OFF, on OFF on: Display shows arc voltage
OFF: Display shows pole voltage
Cable Length
CAb std, 5 – 80m std Cable loss is calculated for optimal arc
control and for the Arc Voltage display
Synergic MIG -welding SETUP -parameters
Name of parameter
Name on
display
Parameter
values
Factory
setting
Description
Pre Gas Time
PrG 0.0 – 9.9 s Syn Pre gas time in seconds or automatically
according to synergic welding program
(Syn)
Post Gas Time
PoG 0.0 – 9.9 s Syn Post gas time in seconds or automatically
according to synergic welding program
(Syn)
Creep Start
Cr OFF, on OFF Switch creep start on or o.
Creep Start Level
CrE 10 – 170% 50% Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start
Hot Start Level
Hot -50 ... 75% 30% Percentage of welding power:
-50% cold and +75% hot
Hot Start 2T Time
H2t 0.0 – 9.9 s 1.2 s The duration of the hot start in seconds in
2T mode
Crater Fill End Level
CrL 10 – 250% 30% The welding power at the end of the crater
ll stage as a percentage of the welding
power preset value
Crater Fill Start Level
CrS 10 – 250% 30% The welding power at the beginning of
the crater ll stage as a percentage of the
welding power preset value
Crater Fill Time
CrT 0.0 – 9.9 s 2.0 s The duration of the crater ll stage in
seconds (only in 2T mode)
Wise Fusion On
FUS OFF, on OFF
Switch Wise Fusion on/o (only in 1-MIG)
Wise Fusion Percent
FUP 10...60% 25%
Percentage of Wise Fusion (only in 1-MIG)
Wise Penetration On
PE OFF, on OFF
Switch Wise Penetration on/o (only in
1-MIG)
Penetration Level
PEn -30 ... +30% 0%
Set the arc length where penetration
control begins (only in 1-MIG)
MiniLog On
ML on, OFF OFF
Switch on/o MiniLog