FastMig MS 200, MS 300
16
EN
Common Setup -parameters for MIG processes
Name of parameter
Name on
display
Parameter
values
Factory
setting
Description
Device Address
Add 3 or 6 3 Wire feeder bus address
Using features of PMT
Gun
Gun OFF, on on on = PMT gun
OFF = other gun
Gas Guard Connected
GG no, YES no Implementation of gas guard
LongSystem Mode
LSY OFF, on OFF on: Gives optimum welding characteristics
with long welding cables. Recommended
to be used when the cable length exceeds
40 m.
Code Entry
Cod ---, Ent --- Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have
been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)
PIN Code Entry
PIn ---, PIn --- Enters pin code for Panel Locking
Panel Locking
LoC OFF, on OFF Enables panel locking
Water Cooler
Coo OFF, on on Enables water cooler
Wire Inch Stop
Inc OFF, on on OFF = Stops wire inch in case arc does not
ignite
on = Feeds wire as long as the welding
gun start switch is pressed.
Auto Wire Inch
AIn OFF, on on SuperSnake Automatic Wire Inch
function. Wire Inch button runs the ller
wire from the wire feeder up to the
SuperSnake.
Demo Licence Time
dEt 3-h, 2-h, **’,
**’, OFF
The remaining time for the WiseDemo
licence
(readable value only).
3-h = max. 3 hours left
2-h = max. 2 hours left
**’ = ** minutes left
**’ = ** seconds left
OFF = Demo period has expired.
Restore Factory
Settings
FAC OFF, PAn, ALL OFF Control panel reset function.
OFF = No reset
PAn = Settings will be restored, but
memory channels remain unchanged
ALL = All settings will be restored to
factory values.