4.3 Welding parameters
MIG
WFSpeed 0.7…25 m/min Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min,
and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
Voltage 8…50 V Step: 0.1 Controls the length of the arc
VoltageMax Sets the limit for maximum voltage value
VoltageMin Sets the limit for minimum voltage value
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
1-MIG
WFSpeed 0.7…25 m/min * Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/
min, and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
FineTuning -9…+9 Factory setting is 0
( = curve point)
Adjusts the arc voltage of the curve (arc length)
within certain limits
FineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc length
FineTuningMin -9…+9 Step: 0.5 Sets the limit for minimum arc length
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
PULSE MIG
WFSpeed 0.7…25 m/min * Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed
< 5 m/min, and by 0.1, when WFSpeed > 5 m/min
WFS-Max Sets the limit for maximum WFSpeed
WFS-Min Sets the limit for minimum WFSpeed
FineTuning -9…+9 Factory setting is 0
( = curve point)
Adjusts the base current of the curve (arc length) in
certain limits
FineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc length
FineTuningMin -9 ... +9 Step: 0.5 Sets the limit for minimum arc length
Dynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Pulse Current -10…+15% Factory setting
is 0 %
Reduces (–) or raises (+) the pulse current of the
curve
FastMig X 450
14

Other manuals for Kemppi FastMig MXF 37 Pipe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig MXF 37 Pipe and is the answer not in the manual?

Kemppi FastMig MXF 37 Pipe Specifications

General IconGeneral
BrandKemppi
ModelFastMig MXF 37 Pipe
CategoryWelding System
LanguageEnglish

Related product manuals