CC PROCESS
Current 10…450 A Welding current
CurrentMax 10…450 A Set the limit for maximum current value
CurrentMin 10…450 A Set the limit for minimum current value
Dynamics -9…+9 Factory setting
is 0
Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher
the value the rougher the arc is.
StartPower -9…+9 Factory setting
is 0
Adjusts arc ignition
CV PROCESS
Voltage 10…50 V Welding voltage
VoltageMax 10…50 V Set the limit for maximum voltage value
VoltageMin 10…50 V Set the limit for minimum voltage value
Dynamics -9…+9 Factory setting
is 0
Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher
the value the rougher the arc is.
StartPower -9…+9 Factory setting
is 0
Adjusts arc ignition
4.4 Welding functions
WISEROOT+ AND OTHER PROCESSES
2T/4T 2T, 4T,
MATCHLOG, USER
Factory setting is USER (user
chooses the switching logic)
Sets switching logic
HotStart ON, OFF, USER Factory setting is USER (user
chooses ON or OFF)
HotStartLevel -50…+100 % Step: 1
Factory setting 40%
Hot 2T Time 0…9.9 s Step: 0.1
Factory setting is 1.2 s
CraterFill ON, OFF, USER Factory setting is USER (user
chooses ON or OFF)
CraterStart 10…250 % Factory setting is 100% Sets the level of the curve where the
crater lling will start
CraterFillEnd 10…250 %, not
higher than start
Step: 1
Factory setting is 30%
Sets the level of the curve where the
crater lling will end.
CraterTime 0.0…10.0 s Step: 0.1.
Factory setting is 1.0 s
Sets slope time for crate lling
Crater 4T Timer On, OFF Factory setting is OFF ON: if 4T is selected, crater lling will
last at least time that has been adjusted
by CraterTime or as long as trigger is
pressed.
OFF: if 4T is selected, crater lling will
last as long as trigger is pressed.
FastMig X 450
16

Other manuals for Kemppi FastMig MXF 37 Pipe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig MXF 37 Pipe and is the answer not in the manual?

Kemppi FastMig MXF 37 Pipe Specifications

General IconGeneral
BrandKemppi
ModelFastMig MXF 37 Pipe
CategoryWelding System
LanguageEnglish

Related product manuals