Operating manual
Manual de instrucciones
Manuel d’utilisation
Manual de utilização
Инструкции по эксплуатации
EN
FR
ES
RU
PT
HiArc
M 400R, M 500R

Questions and Answers

  • S
    Sarah PerezAug 8, 2025
    What to do if Kemppi HiArc M 500R overheats and shows Err 4?
    • T
      Taylor MartinezAug 9, 2025
      The Kemppi Welding System may have stopped working due to overheating or exceeding the duty cycle. Ensure unrestricted airflow for cooling. If the duty cycle has been exceeded, the fan should start, and the machine will recover in a few minutes. If the problem persists, contact a Kemppi service representative.
  • Q
    qkennedyAug 15, 2025
    What to do if Kemppi Welding System shows Err 2 or Err 3?
    • K
      Kelly SmithAug 15, 2025
      The Kemppi Welding System has stopped because the mains voltage is either too low (Err 2) or too high (Err 3). The machine will automatically recover when the mains voltage is within the recommended range of 342 – 484 V.
  • P
    Patricia JacksonAug 21, 2025
    What to do if Kemppi HiArc M 500R Welding System displays Err 43 error?
    • P
      patrickserranoAug 21, 2025
      The Kemppi Welding System stopped working and shows Err 43 because the wire feeder motor is overloaded. Check that you are using the correct wire type and that the wire feed path is not blocked.
  • T
    Taylor MirandaAug 27, 2025
    Why is the Kemppi Welding System producing poor welding results?
    • A
      Anthony MerrittAug 27, 2025
      Several factors can affect the welding quality. Here's what to check: * Verify wire feed calibration. * Ensure the earth return clamp is properly attached and the contact point is clean, and that the cable and connectors are intact. * Confirm the voltage and wire speed settings on the control panel are correct for the wire size and type being used. * Make sure the shielding gas flow rate at the gun nozzle is correct. * Ensure the shielding gas is suitable for the filler wire used. * Check that the wire feed is constant, and adjust if necessary. * Verify that the mains voltage is not too irregular.
  • T
    thomasmortonSep 2, 2025
    How to troubleshoot the main switch indicator on Kemppi HiArc M 500R Welding System?
    • B
      Brittany PorterSep 2, 2025
      The main switch indicator on the Kemppi Welding System isn't turning on because the machine isn't receiving mains voltage. Check the mains fuses, the mains cable, and the wall plug.

Summary

Installation and Setup Guide

Mains Electrical Connection Procedure

Details how to connect the machine to an earthed 3-phase power supply using the terminal strip.

Operating the HiArc Welding Machine

2 T Trigger Logic and Crater Fill

Explains the 2T and 2T with Crater Fill modes for welding trigger operation.

4 T Trigger Logic and Crater Fill

Details the 4T trigger mode operation and its variant with crater fill functionality.

Wire Feed Speed Calibration Procedure

Step-by-step guide to calibrate the wire feed speed for the power source and wire feeder.

Troubleshooting Welding Issues

Common Welding Problems and Causes

Lists common problems like overheating, voltage errors, and poor welding with their respective causes and solutions.

Technical Specifications

Kemppi HiArc M 500R Specifications

General IconGeneral
Input Voltage3 x 400 V
Output Current MIG500 A
TypeMIG/MAG welding equipment
Welding ProcessesMIG/MAG
Duty Cycle60% at 500 A, 100% at 400 A
CoolingWater-cooled
Enclosure ClassIP23