EasyManua.ls Logo

Kemppi MasterTig MLS 3003 ACDC - SETUP Function Details; Detailed Setup Options Configuration

Kemppi MasterTig MLS 3003 ACDC
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
A002 Auxiliary power card
Functions and connectors
A002 Auxiliary Power Supply Main Functions
- output voltage 24Vdc
- input voltage range (450 … 750)Vdc (X1, X3)
- output power 100W continuous with forced cooling
- switching frequency 100kHz
- topology flyback
- forced “hiccup” mode in overload (X17 off)
- over voltage switch off about 830Vdc
- low voltage wake-up 200Vdc
- supply 24Vdc also to water cooler unit
- floating secondary inverter gate drive voltages 35Vdc
- supply also auxiliary power to pre-inverter and
primary diode card 35Vdc (X2)
primary
secondary
X17 = no forced “hiccup” mode
H5 = gate voltage aid+
H4 = gate voltage dc+
H1 = 24Vdc
H2 = gate voltage aid-
H3 = gate voltage dc-
Factory setting
X17 = off

Other manuals for Kemppi MasterTig MLS 3003 ACDC

Related product manuals