EasyManua.ls Logo

Kemppi MasterTig MLS 3003 ACDC - Page 21

Kemppi MasterTig MLS 3003 ACDC
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Measurements
Z001, Main circuit card :
- Power should be off !
- With these measurements you can find short circuits and partly open circuits that indicates fault in
the machine.
- Measure diodes in forward and reverse direction. Forward diode threshold voltage is ~0,4V, reverse
direction infinite. See the picture below for instructions.
- Repeat measurements for all four (4) instances. Pin locations marked in the pictures below.
- Remember that MLS 3000 ACDC and 3003 ACDC have different Z001 cards !
Diodes* Measuring points Value
1. 2 -> 22 ~ 0,4 V
2. 8 -> 12 ~ 0,4 V
3. 24 -> 17 ~ 0,4 V
4. 10 -> 14 ~ 0,4 V
12
10
14
22
17
2
24
8
Diode 2.
Diode 3.
Diode 3.
Diode 2.
2.
3.
4.
1.
* Diodes marked with red color in the right hand picture.

Other manuals for Kemppi MasterTig MLS 3003 ACDC

Related product manuals