Questions and Answers

  • J
    Jeffrey DavisAug 6, 2025
    Why is my Kemppi Minarc 120 AU Welding System producing poor welding results?
    • S
      Shannon DelgadoAug 6, 2025
      Several factors can lead to poor welding results. Make sure the earthing clamp is firmly attached to a clean attachment point, and that the cable and its connectors are in good condition. Also, verify that the shielding gas flows correctly from the torch tip and that the electric voltage is stable and within the correct range.
  • K
    Kelly DavisAug 20, 2025
    What to do if the overheating indicator is lit on my Kemppi Welding System?
    • G
      gwilliamsAug 20, 2025
      If the overheating indicator is on, it means the device has overheated. To resolve this, ensure that the cooling air can flow without any restrictions. If you've exceeded the machine's duty cycle, wait for the indicator to turn off. Also, check for supply voltage issues.

Summary

PREFACE

Safety instructions

Crucial guidelines for safe operation and preventing hazards.

BEFORE YOU START USING THE UNIT

Connecting to power supply mains

Procedure for safely connecting the unit to the electrical power source.

USE

Welding processes

Explanation of Manual Metal Arc (MMA) and TIG welding processes.

Operating functions

Description of the unit's controls, indicators, and their functions.

WELDING SELECTIONS

Manual Metal Arc Welding (MMA)

Select welding parameters for MMA welding based on filler manufacturer's recommendations.

MAINTENANCE

TROUBLESHOOTING

TECHNICAL DATA

WARRANTY POLICY

Kemppi Minarc 120 AU Specifications

General IconGeneral
Input Voltage230 V
Output Current Range10 - 120 A
Input Current16 A
Electrode Size1.6 - 4.0 mm
Welding Current Range10 - 120 A
Protection ClassIP23
Dimensions99 x 203 x 230 mm
ProcessMMA