READ BEFORE iNSTALLiNG UNiT
For Slider Casement Air Conditioners
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp
edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to
move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over
an extended period of time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp
metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or
installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.
A high window accessory kit is available for window heights up to 62" (1575 mm). Part # EA103W.
Call 1-800-4-MY-HOME to order kit.
Meeting Electrical Requirements
Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance.
o DO NOT ground to a gas line.
If cold water pipe is interrupted by plastic, non-metallic gaskets, or other insulating materials, DO NOT use for
grounding.
Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
DO NOT modify power supply cord plug. If it does not fit outlet, have a proper outlet installed by a qualified
electrician.
o DO NOT have a fuse in the neutral or grounding circuit. Afuse in the neutral, or grounding circuit could result in
an electrical shock.
DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury, or death.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES. DO NOT, UNDERANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.
If codes permit, and a separate grounding wire is used, it is recommended that a qualified electrician determine
that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating
materials.
2020217A1406
Question and Answer IconNeed help?

Do you have a question about the Kenmore 25371123011 and is the answer not in the manual?

Summary

Safety and Electrical Guidelines

General Safety Precautions

Covers CAUTION for injury, property damage, or product damage due to weight and sharp edges.

Electrical Safety and Requirements

Details electrical grounding, wiring, receptacle requirements, and shock/injury hazards.

Installation Preparation and Tips

Preparation and Installation Tips

Provides guidance on window types, framing, and general installation advice.

Window Sizing and Parts

Specifies required window dimensions and lists contents of the installation kit.

Sliding Window Installation

Sliding Window Platform and Brace Setup

Instructions for attaching the support brace to the platform and initial window placement.

Sliding Window Panel and Seal Installation

Details on cutting the window panel, attaching side channels, and applying seals.

Sliding Window Unit Placement and Securing

Guidance on positioning the unit, securing the sash, and replacing the front panel.

Sliding Window Jamb Adjustments

Steps for drilling holes, attaching the platform, and adjusting for water drainage.

Sliding Window Final Assembly

Completes installation by sealing channels, securing the unit, and replacing the front.

Casement Window Installation and Jambs

Alternate Window Jamb Applications

Provides methods for installing in windows without standard flanges or wood stops.

Casement Window Installation Steps

Details on platform attachment, window clearance, and options for stationary sash.

Summary

Safety and Electrical Guidelines

General Safety Precautions

Covers CAUTION for injury, property damage, or product damage due to weight and sharp edges.

Electrical Safety and Requirements

Details electrical grounding, wiring, receptacle requirements, and shock/injury hazards.

Installation Preparation and Tips

Preparation and Installation Tips

Provides guidance on window types, framing, and general installation advice.

Window Sizing and Parts

Specifies required window dimensions and lists contents of the installation kit.

Sliding Window Installation

Sliding Window Platform and Brace Setup

Instructions for attaching the support brace to the platform and initial window placement.

Sliding Window Panel and Seal Installation

Details on cutting the window panel, attaching side channels, and applying seals.

Sliding Window Unit Placement and Securing

Guidance on positioning the unit, securing the sash, and replacing the front panel.

Sliding Window Jamb Adjustments

Steps for drilling holes, attaching the platform, and adjusting for water drainage.

Sliding Window Final Assembly

Completes installation by sealing channels, securing the unit, and replacing the front.

Casement Window Installation and Jambs

Alternate Window Jamb Applications

Provides methods for installing in windows without standard flanges or wood stops.

Casement Window Installation Steps

Details on platform attachment, window clearance, and options for stationary sash.

Kenmore 25371123011 Specifications

General IconGeneral
BrandKenmore
Model Number25371123011
TypeWindow Air Conditioner
Room Size CoverageUp to 350 sq. ft.
Voltage115V
Amperage6.5A
Number of Cooling Speeds3
Number of Fan Speeds3
Filter TypeWashable
Installation TypeWindow