EasyManua.ls Logo

Kenmore 721.80039 - Step 1: Prepare the Electrical Connections; Avoid Electrical Shock! This Appliance Must Be Grounded!; Do Not, Under Any Circumstances, Remove the Power Supply Cord Grounding Prong!

Kenmore 721.80039
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STEP1: PREPARETHEELECTRICALCONNECTIONS
WARNING
AVOID ELECTRICAL SHOCK[ THIS APPLIANCE MUST BE GROUNDED[
1. Locate the grounded electric outlet for this oven in the cabinet
above the oven, as shown in Figure 4 Detail.
NOTE: The outlet should be on a circuit dedicated to the
microwave oven 120V, 60Hz., AC only, with a 20ampere
fused electrical supply.
IMPORTANT: If you do not have the proper wail outlet, you
MUST have one installed by a qualified electrician.
2. You will cut the power-supply-cord hole (shown in Figure 4 Detail)
later when you prepare the wail and upper cabinet in Step 4.
NOTE: Do not use an extension cord. Keep the power cord dry and
do not pinch or crush it.
Upper Cabinet
...................................
0
1
Power-Supply-Cord Hole
Grounded
Outlet
Figure 4 Detai[
_, WARNING
improper grounding could result in electric shock or other personal injury.
• DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLYCORD
GROUNDING PRONG[
This appliance MUST be grounded[
7