EasyManua.ls Logo

Kenmore 795.72033 - Page 26

Kenmore 795.72033
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 26 -
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-3)
Result SVC Action
8-4 Defrost Sensor Error (F dS)
No
1
2
Checking flow
Check for a loose connection.
Check the Orange to Orange.
Result & SVC Action
Check the Brown to Brown at
CON7 on the main PCB
<CON7>
<Temperature table-3>
(1) To (2)
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38 ㏀
30 ㏀
24 ㏀
19.5 ㏀
16 ㏀
※
The sensor is determined by
the temperature.
For example, 30㏀ indicates 32°F.
Appliantology.org