EasyManua.ls Logo

Kenmore 795.72033 - Page 27

Kenmore 795.72033
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 27 -
8-5 Defrost Heater Error (Er dH)
Fuse-M
Def’
Heater
Def’
sensor
0
Ω
Other
34~42
Ω
Other
0
Ω
OFF
Go to the 3
Change Controller Assembly
(Position No.400A )
Go to the 3
Change Controller Assembly
(Position No.400A )
Go to the 3
Replace product
Part Result SVC Action
No
1
2
Checking flow
Check the Door gasket.
Check the Defrost control part.
3 Input Test 3 Mode.
(Push the button 3 times)
4 Check the Blue(Pin4) to Orange
(Pin9) at CON3 on the main PCB
Result & SVC Action
Def' Heater
Fust
M
Def'
Sensor
5 Release the test mode.
push the button 1 times. (normal)
<CON3>
Result
112 ~ 116 V
0 V
SVC Action
Go to the 5
Replace Main PCB
6 Check the Blue(Pin4) to Orange
(Pin9) at CON3 on the main PCB
Result
0 V
112 ~ 116 V
SVC Action
Explain to customer
Replace Main PCB
<CON3>
Appliantology.org