PARAMETER TABLE PARAMETER TABLE
password
probe measurement stability
probe display rate
select probe displayed
select °C/°F (0:centi degree 1:fahrenheit)
disable decimal point (0:disable dp.)
enable probe 2 alarm(1:alarm) (reserved)
probe 1 offset
probe 2 offset
probe 3 offset
select type of probe (reserved)
set point
differential
minimum set point value
maximum set point value
select direct/reverse operation
(0: direct with defrost
(1: direct without defrost
(2: reverse without defrost)
night-time set point delta
compressor and fan start delay on
minimum compressor off time
minimum time between consecutive
compressor starts
200 22
15
4
15
4
3
1
1
0
1
0
1
0
50
0.0°C
50
50
1
0 -
r2
4.0°C
19
2.0
r2
-2°C
r1 200
8°C
°C/°F
0.0°C °C/°F
0.0°C °C/°F
°C/°F
°C/°F
°C/°F
°C/°F
Type Min Max Def. Unit
F 0
C 1
F 0
F 1
F 0
F 0
F 0
F -50
F -50
F -50
C 0
F r1
F 0
C -50
C
Description Description
Par. Disp.
PS
/2
/3
/4
/5
/6
/7
/C1
/C2
/C3
/P
St
rd
r1
r2
r3
minimum compressor on time
compressor on time with duty setting
(0:off,100:always on)
continuous cycle duration (reserved)
temperature alarm bypass after
continuous cycle (reserved)
second compressor delay(reserved)
r4
c0
c1
c2
c3
c4
cc
c6
c11
C 0 2 0 -
C -50 50
3.0°C
C 0 100 0 min
C 0 100 0
min
C 0 100 0
min
C 0 100 0
min
C 0 100 0
min
C 0 15 0 h
C 0 15 2 h
C 0 250 4 s
°C/°F
-
-
-
-
-
-
-
type of defrost
(0=heater, end by temperature
(1=hot gas, end by temperature
(2=heater, end by time
(3=hot gas, end by time
(4= heater with temperature control,
end by time)
interval between defrosts
end defrost temperature set point
maximum defrost duration
defrost when switching the instrument
on (0:disable 1:enable)
defrost delay on power-up or when
enabled by digital input
freeze control temperature display
during defrost
(0: display the message“dF”alternating
with the temperature measured by
the control probe;
(1: freeze the display on the last
temperature measured before
the defrost)
time base
(0:dl uint=hour, dP unit=min
(1:dl uint=min, dP unit=second)
alarm and fan temperature differential
(A0≤0, AL and AH expressed as
absolutes (A0>0, AL and AH expressed
relative to the set point)
dripping time
alarm bypass time after defrost
defrost priority over compressor
protectors (0: protection times
observed (1: protection times ignored)
defrost probe reading
Type Min Max Unit
C 0 4 0 -
F 0 199 8 h/min
F -50 130 4.0
F 1 199 30 min/s
C 0 1 0 -
C 0 199 0 min
C 0 1 1 -
C 0 1 0 -
C -20 20 2.0
F 0 15 2 min
F 0 15 1 h
C
0 1 0 -
F - -
°C/°F
°C/°F
°C/°F
Par. Disp.
d0
dl
dt
dP
d4
d5
d6
dC
A0
dd
d8
d9
d/
absolute/relative temperature for
low temperature alarm
absolute/relative temperature for
high temperature alarm
F -50 250 0
F -50 250 0
°C/°F
°C/°F
AL
AH