Do you have a question about the Kenwood kac-829 and is the answer not in the manual?
Connect DC voltmeter to CN3 (L/R) and J3 (SP.OUT,L+/R-) to measure idle current.
Connect DC voltmeter to CN3 (L/R) and J3 (SP.OUT,L+/R-) to measure idle current.
| max power output (4Ω) normal | 200W × 2 |
|---|---|
| max power output (4Ω) bridge | 600W × 1 |
| rated power output (4Ω) normal (20Hz ~ 20kHz, 0.08% THD) | 100W × 2 |
| rated power output (4Ω) normal (DIN45324, +B =14.4V) | 100W × 2 |
| rated power output (4Ω) bridge (1kHz, 0.8% THD) | 300W × 1 |
| rated power output (2Ω) normal (1kHz, 0.8% THD) | 150W × 2 |
| frequency response (+0, -1dB) | 5Hz ~ 50kHz |
| signal to noise ratio | 100dB |
| sensitivity (MAX) (rated output) | 0.2V |
| sensitivity (MIN) (rated output) | 5.0V |
| input impedance | 10kΩ |
| low pass filter (12dB/oct.) | 80Hz |
| operating voltage | 14.4V |
|---|---|
| current consumption (1kHz, 10% THD) | 28A |
| dimensions (width × height × depth) | 221mm × 57mm × 300mm |
| weight | 3.8kg |