30 FKB-BA-e-2010
Audio signal:
The acoustic signal depends on the menu setting
< setup beeper >, see chap. 13.3.1.
Procedure:
1. Define upper and lower limit value:
Make sure that the balance is in weighing mode. If necessary, switch over with the
Press the TARE button and keep it pressed until the first menu item < limit >
will be displayed.
Confirm with button. < limlow > will be displayed.
Press button to confirm, the numeric input window for entering the lower limit
value will appear. Enter the lower limit value for the target piece quantity (numeric
input see chap. 3.2.2) and confirm with button.
The balance returns to the < limlow > menu.
Use the navigation keys to select the setting < limupp > and confirm with
button.
The numeric input window for entering the upper limit value < will appear. Enter the
upper limit value for the target piece quantity (numeric input see chap. 3.2.2) and
confirm with button. < limupp > will appear.
Press repeatedly button to exit menu.
Finished the setting works, the weighing balance is ready now for check weighing.
2. Start tolerance check:
Place the weighed material and check by means of the tolerance marks / acoustic
signal if the weighed material is within the defined tolerance.
Load below specified
tolerance
Load within specified
tolerance
Load exceeds specified
tolerance

Table of Contents

Other manuals for KERN FKB 8K0.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KERN FKB 8K0.1 and is the answer not in the manual?

KERN FKB 8K0.1 Specifications

General IconGeneral
BrandKERN
ModelFKB 8K0.1
CategoryScales
LanguageEnglish

Related product manuals