KD GEMINI INSTALLATION/OPERATION MANUAL
KD Gemini May-06
13
OPENING HEIGHTS from floor
Burner c/l 11 5/8” (295 mm)
Smoke pipe c/l 39 3/16” (995 mm)
SMOKE/VENT PIPE CONNECTIONS
5” Chimney
4” Direct Vent
CLEANOUTS
View port, Front Cleanout, Smoke pipe and Burner opening
AIR FILTERS 20” x 24” x 1”
FUEL not heavier than No. 2 furnace oil.
ELECTRICAL 120 Volts, 60 Hz
Canada Less than 12 amps.
USA 13.3 amp, circuit protection 20 amps.
This furnace has been tested to and meets the requirements of B212-93 Seasonal
Energy Utilization Efficiencies of Oil-Fired Furnaces & Boilers & the Energy-Efficient
Appliances Act of 1991.
Certified for use with Type “A” or Type “L” vent maximum flue gas temperature 575°F.
Certified for use with Kerr Direct Vent.
Certified for use with Kerr KPV-SS1C through-the-wall mechanical vent system.
10.0 TROUBLE SHOOTING GUIDE
Furnace will not start
Tripped blocked vent switch Clear vent, reset switch.
Tripped breaker Determine cause, reset breaker.
Blown fuse Replace fuse.
No oil Check tank for leaks and call oil supplier.
Oil burner keeps turning off
Dirty air filter Change air filter.
Restricted air supply/return Check all air return/supply registers.
Limit control Check ductwork for blockage.
Motor over heating Check motor speed for correct nozzle on furnace
label settings.
Dirty nozzle Call technician to replace nozzle.
Sooty flame
Wrong pump pressure Increase or decrease pressure to correct setting.
Dirty nozzle Replace nozzle.
Improper burner setting See “BURNER SPECIFICATIONS”.
Barometric draft wrong Adjust barometric regulator for -0.04” wc draft
pressure at breech.