EasyManuals Logo

Kestrel 5500 User Manual

Kestrel 5500
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22
FDFM – Fine Dead Fuel Moisture, also known as 1 Hr
Moisture Content, is an estimate of the moisture content of
dead fuel between 0-1/4” in diameter.
HEAT INDEX – Heat Index is a calculated value of the
perceived temperature based on temperature and relative
humidity.
GLOBE TEMP Globe Temperature is dened as the
temperature measured inside a 6-inch copper globe
painted black. On the Kestrel HST, the temperature inside
the 1-inch|25 mm globe is converted to the equivalent
temperature for a standard globe. The closest equivalence
will be obtained with airow greater than 2.2 mph|1 m/s.
NWB TEMP Natural Wet Bulb Temperature is a measure
of evaporative cooling in an environment with unforced,
naturally occurring air ow.
WBGT – Wet Bulb Globe Temperature is a measure of human
heat stress resulting from the combination of eects due
to temperature, humidity, wind speed (wind chill), and
visible and radiant heat. Outdoor WBGT is calculated from
a weighted sum of Natural Wet Bulb Temperature, Globe
Temperature and dry bulb Temperature.
TWL – Thermal Work Limit is a measure of the heat
energy a person can dissipate from their surface area in
Watts per square met
DEW POINT – Dew Point is the temperature at which
water vapor will begin to condense out of the air.
WET BULB – Wet Bulb is the lowest temperature that
can be reached in the existing environment by cooling
through evaporation. Wet Bulb is always equal to or
lower than ambient temperature.
BARO – Barometric Pressure is the local station (or
absolute) pressure with the pressure dierential
associated with the locations altitude above sea level
subtracted. An accurate reading depends on an
accurate initial altitude input and unchanging altitude
while measuring.
ALTITUDE – Altitude is the change in vertical distance
associated with a change in atmospheric pressure.
An accurate reading depends on an accurate initial
barometric pressure input and stable barometric
pressure while measuring.
STATION – Station Pressure (Absolute Pressure) is the
pressure exerted by the earth’s atmosphere at any
given point.
DENS ALT – Density Altitude is the altitude at which
the density of the theoretical standard atmospheric
conditions (ISA) would match the actual local air
density.
www.CanarySense.com
Shop for Gas products online at:
1.888.610.7664

Other manuals for Kestrel 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kestrel 5500 and is the answer not in the manual?

Kestrel 5500 Specifications

General IconGeneral
Humidity Range0 to 100% RH
Water ResistanceIP67
Data LoggingYes, up to 10, 000 data points
Bluetooth ConnectivityYes
Measurement ParametersWind Speed, Temperature, Humidity, Pressure
Temperature Range-20°C to 70°C
Pressure Range300 to 1100 hPa
AccuracyWind speed: ±3%, Temperature: ±1°C, Humidity: ±2% RH, Pressure: ±1.5 hPa
DisplayBacklit LCD
Battery Life400 hours

Related product manuals