PARAMETERS DESCRIPTION DEFAULT MIN MAX UNIT
1
TCL
Automatic reclosure time (0 = off) 0 0 900 s
2
ttr
Reclosing time after transit on PH1
(0 = off)
0 0 30 s
3
SEI
Sensitivity on obstacles
0 = Maximum impact force
10 = Minimum impact force
3 0 10
4
SFO
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
5
SSO
Motor speed during opening deceleration phase
1 = minimum *
2 = low *
3 = medium
4 = high
5 = maximum
1 1 5
6
SFC
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
7
SSC
Motor speed during closing deceleration phase
1 = minimum *
2 = low *
3 = medium
4 = high
5 = maximum
1 1 5
8
SBS
STEP BY STEP or SBS conguration:
0 = Normal (AP-ST-CH-ST-AP-ST…)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH…)
2 = Alternate (AP-CH-AP-CH…)
3 = Apartment block – timer
4 = Apartment block with immediate reclosure
0 0 4
9
LSI
Deceleration distance
0 to 100 = Motor deceleration percentage during
opening and closure
20 0 ** 100 %
10
BlT
Post blackout procedure
0 = No action, remains stationery
1 = Closure
0 0 1 s
11
SBY
Energy saving: enables photocell switch-off when gate
is closed
0= disabled
1= enabled
0 0 1
* = only for SUN4224/SC4224