4
EN
230 Vac
230 Vac
24 Vac
24 Vac
PH1
2
1
4
3
6
5
8
7
10
11
12
13 14
15
16
17
9
STOP
SS
CLOSE
OPEN
OPEN
CLOSE
COM
COM
SELECTION
MODE
MEMORY
FUSE
6,3 A
A.R
W.T
CD.
MAX
MIN
J1
J2
J3
J4
J5
10
9
6
7
5
8
4
1
2
11
12
3
2.1 - Description of the control unit
Control unit for a motor in alternatine current with torque adjuster, output
contact for limit switch or open/close bottons, selectable, output contact
for photo dispositive, stop button, step-by-step, with radio modular and
2.2 - Description of the connections
1- Motor power supply connections
2- 230 Vac power supply connections (50-60 Hz)
3- Connection to ashing light
4- 24 Vdc power supply connection to controls and safety devices
5- RED programming LEDs
6- Radio module
7- Antenna connector
8- SELECTION button
9- MODE button
10- Jumpers functions
11- 6.3 A rapid fuse protecting the line
12- Trimmer adjustment of torque
2.3 - Models and technical characteristics
memory extractable. This control unit has been designed for the auto-
mation of rolling shutters, shutters and sliding doors.
2 - INTRODUCING THE PRODUCT
CODE DESCRIPTION
900CT1RD 230 Vac control unit for one motor for rolling shutter or sliding gate with electric clutch, limit switch and receiver