Keysight FieldFox Handheld Analyzers Service Guide 85
Theory of Operation
Firmware Related Information
Firmware Related Information
General Description
The analyzer is based on the Windows CE operating system. This is a closed
system; no direct user access to the desktop of general operating system
functions is provided.
The file system for Windows CE is maintained in flash memory on the A6 SOM
board. There is limited access to the file system. Most memory is in a protected
region and not directly accessible by the user.
The user accessible memory is under UserData. See the “File Management”
section of the FieldFox Analyzer User’s Guide (Part Number N9927-90001) for
instructions on saving, recalling, and managing files in the unprotected
memory.
User Accessible Files
Directory structure below UserData in the A6 SOM board flash memory.
External USB flash memory plugged in the analyzer.
External SD memory card plugged into the analyzer.
NOTE: When copying files, a “Copy_....” directory is created at the root of the
destination device as the destination for the copied file(s). This characteristic
generally makes it impossible to copy a file into the desired directory under
UserData in the A6 SOM board flash memory. This limits the usefulness of
copying files to or within UserData.
Operational Files
Results from adjustments performed under TME (see Chapter 3)—not
directly available to user.
File resulting from CAT/NA/VVM user calibration—not directly available to
user.
Cal kit definition files—stored in UserData\calkits.
Cable definition files—stored in UserData\Cables.
Error log—not directly available to user. See “Error Log” further on in this
section for accessing error log information.
Erase User Data Utility
A utility to erase all directories and files in the UserData directory is available.
After the flash memory is erased, the boot process returns the UserData
directories and files to the state as shipped from the factory.

Table of Contents

Other manuals for Keysight Technologies FieldFox N9938A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies FieldFox N9938A and is the answer not in the manual?

Keysight Technologies FieldFox N9938A Specifications

General IconGeneral
BrandKeysight Technologies
ModelFieldFox N9938A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals