EasyManua.ls Logo

Keysight E3633A - Page 124

Keysight E3633A
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Remote Interface Reference
124 Keysight E3633A and E3634A User’s Guide
OUTPut:RELay {OFF|ON}
This command sets the state of two TTL signals on the RS-232 connector.
These signals are intended for use with an external relay and relay driver. The
TTL output is available on the RS-232 connector pin 1 and pin 9. When the
OUTPut:RELay
state is “ON”, the TTL output of pin 1 is high (4.5 V) and pin 9 is
low (0.5 V). The levels are reversed when the
OUTPut:RELay
state is “OFF”. At
*RST
, the
OUTPut:RELay
state is OFF.
OUTPut:RELay?
This command returns the state of the TTL relay logic signals. See also
OUTP:REL
command.
SYSTem:BEEPer
This command issues a single beep immediately.
NOTE
TTL output of pin 1 or pin 9 of the RS-232 connector is available only after
installing two jumpers inside the power supply. See the Service Guide for more
information.
NOTE
Do not use the RS-232 interface if you have configured the power supply to
output relay control signals. Internal components on the RS-232 circuitry may
be damaged.

Table of Contents

Related product manuals