Output Voltage Range | 0 to 20 V |
---|---|
Output Current Range | 0 to 10 A |
Number of Outputs | 1 |
Programming Resolution Voltage | 1 mV |
Programming Resolution Current | 1 mA |
Programming Accuracy (Voltage) | 0.05% + 10 mV |
Programming Accuracy (Current) | 0.1% + 5 mA |
Readback Accuracy (Current) | 0.1% + 5 mA |
Line Regulation | 0.01% + 2 mV |
Load Regulation | 0.01% + 2 mV |
Overtemperature Protection | Yes |
Remote Sensing | Yes |
Operating Temperature | 0 to 50 °C |
Storage Temperature | -40 to 70 °C |
Cooling | Forced air |
Interface | GPIB, USB, LAN |
Readback Resolution | 1 mV |
Temperature Coefficient | 100 ppm/°C |
Overvoltage Protection | Yes |
Input Voltage | 100 to 240 VAC |
Input Power | 300 W max |
Safety Standards | UL 61010-1, CSA C22.2 No. 61010-1, EN 61010-1 |
EMC Standards | EN 55011 |
Description of the front panel controls, indicators, and displays for easy identification.
Description of the rear panel connectors, switches, and ports for connectivity.
Detailed instructions for connecting the AC power cord to the unit.
Guidance on selecting wire sizes and connecting loads to the output terminals.
Instructions for connecting multiple units in parallel to increase current capability.
Instructions for connecting multiple units in series to increase voltage capability.
Steps to verify proper operation and configuration before normal use.
Explanation of over-voltage, under-voltage, and over-current protection.
Guide to connecting and configuring GPIB, USB, and LAN interfaces.
Introduction to the SCPI language structure, syntax, and programming concepts.
A comprehensive list of SCPI subsystem and common commands.
Details SCPI commands for programming voltage, current, and protection.
Describes SCPI commands for managing the instrument's status registers.
Example program demonstrating voltage, current, and protection setup.
Example program for setting up and triggering voltage/current changes.
Warranted performance specifications for the N5700 series power supplies.
A dimensional line drawing showing the physical layout and dimensions.
Tests to confirm normal operation and adherence to published specifications.
Step-by-step instructions for calibrating the power supply functions.
Procedures to diagnose and identify causes of improper operation.
A list of SCPI error messages, their meanings, and potential causes.
Highlights general differences in command behavior compared to 603xA models.
Lists compatibility commands and their similar SCPI equivalents.