Remote Interface Reference 4
Keysight E3633A and E3634A User’s Guide 141
STATus:QUEStionable?
This command queries the Questionable Status event register. The power 
supply returns a decimal value which corresponds to the binary-weighted sum 
of all bits in the register. These bits are latched. Reading the event register 
clears it.
STATus:QUEStionable:ENABle <enable value>
This command enables bits in the Questionable Status enable register. The 
selected bits are then reported to the Status Byte.
STATus:QUEStionable:ENABle?
This command queries the Questionable Status enable register. The power 
supply returns a binary-weighted decimal representing the bits set in the 
enable register.
*CLS
This command clears all event registers and Status Byte register.
*ESE<enable value>
This command enables bits in the Standard Event enable register. The selected 
bits are then reported to the Status Byte.
*ESE?
This command queries the Standard Event enable register. The power supply 
returns a decimal value which corresponds to the binary-weighted sum of all 
bits in the register.
*ESR?
This command queries the Standard event register. The power supply returns a 
decimal value which corresponds to the binary-weighted sum of all bits in the 
register.
*OPC
This command sets the “Operation Complete” bit (bit 0) of the Standard Event 
register after the command is executed.