EasyManua.ls Logo

Keysight N8700 - Equipment Required

Keysight N8700
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B Verification and Calibration
100 Series N8700 User’s Guide
Equipment Required
The equipment listed in the following table, or the equivalent to this
equipment, is required for the calibration and performance tests.
Test records for all models are at the end of this verification section.
Type Specifications Recommended Model
Digital Voltmeter Resolution: 10 nV @ 1V; Readout: 8 1/2 digits;
Accuracy: 20 ppm
Keysight 3458A or equivalent
Current Monitor
15A (0.1) 0.04%, TC=4ppm/C
100A (0.01) 0.04%, TC=4ppm/C
300A (0.001) 0.04%, TC=4ppm/C
500A (0.0005) 0.04%, TC=4ppm/C
Guildline 9230/15
Guildline 9230/100
Guildline 9230/300
Guildline 9230/500
Load Resistor
(nominal values)
For 3.3 kW models:
0.02, 0.03, 0.068, 0.12, 0.27, 0.47, 1.1, 1.9,
3.0, 6.8, 27.3, 109 - all resistors 3.5 kW minimum.
For 5 kW models:
0.08, 0.176, 0.32, 0.705, 1.23, 2.0, 4.40,
17.6, 70.6 - all resistors 5.5 kW minimum.
Electronic Load 150V, 400A, 3.3kW minimum for Models N8731- N8740A
150V, 250A, 5kW minimum for Models N8754- N8760A
600 V, 300 A, 5kW minimum - optional for models
N8741A, N8742A, N8761A, N8762A
Keysight N3300A mainframes (up to
4); Keysight N3305A modules (up to
11); Keysight N3306A modules (up to
9)
Amrel Model PLA-5K-600-300
GPIB Controller Full GPIB capabilities - for calibrating over the GPIB Keysight 82350B or
equivalent
Oscilloscope Sensitivity: 1 mV: Bandwidth Limit: 20 MHz
Probe: 1:1 with RF tip
Keysight Infiniium or equivalent
RMS Voltmeter True RMS; Bandwidth: 20 MHz; Sensitivity: 100V Rhode and Schwartz Model URE3 or
equivalent
Differential
Amplifier
Bandwidth: 20 MHz LeCroy DA1855A, DA1850A,
or equivalent
Differential Probe 100:1/10:1 selectable LeCroy DXC100A or eqivalent
Terminations 1 50W BNC termination
Variable-voltage
xfmr or AC source
Power: 3 Phase 24KVA; Range: 180-235V 47 - 63Hz;
360- 440V 47 - 63Hz
Superior Powerstat
1156DT-3Y, 0-280V, 50A,
24.2 KVA or equivalent
Test Records
Test records for each power supply model are provided after the test
procedure sections.
3.3 kW test records are provided followed by the 5 kW test records.

Table of Contents

Related product manuals