EasyManua.ls Logo

Kia EV9 - High-Voltage Service Interlock Connector Disconnection

Kia EV9
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. DISABLE DIRECT HAZARDS / SAFETY REGULATIONS
WARNING
Wait more than 5 minutes for capacitor
of the high-voltage battery system to be
discharged completely.
* If the release button does not work, pull
the emergency lever twice after removing
the emergency open cover located on the
left hand side of the footrest.
4. Separate the 12 V auxiliary battery
negative terminal (A) after loosening the
nut.
5. Remove the PE room junction box cover.
6. Disconnect the high voltage service
interlock connector (A).
Before
After
Kia EV9
Emergency Response Guide
8