For multiple amplifier installations where distribution
blocks are used, each amplifier should have its
proper-rated fuse, or breaker, installed between the
amplifier and the distribution block within eighteen
inches of the block, or on the distribution block if it
provides for fusing. The primary power wire should
also be fused between the battery and distribution
block, within eighteen inches of the battery’s positive
terminal, with a fuse or breaker rated at least to the
sum of the individual amplifiers fuse values, but
doesn’t exceed the capacity of your wiring.
12V
external fuse
to amplifiers
≤18”
(45cm)
external fuse
≤18”
(45cm)
external fuse
power distribution block
battery
≤18”
(45cm)