6
3. Other Alarm Visual And Audible Indicators
Operational Mode Visual Indications Audible Indications Action/Note
Normal (standby)
AC power: Green LED on
continuously.
DC power: Green LED blinks
approx every 60 sec.
Test (button press when
no alarm condition is
present)
(Note: Test is very loud,
stand a few feet away.)
Red LED blinks in time with
alarm pattern.
• • Single beep.
• 3 long beeps, voice “Fire!,”
3 long beeps.
Perform button press once a week
to verify proper alarm operation.
Smoke Alarm Memory
(unit has experienced a
smoke event.)
Red LED blinks
every 15 sec.
After button push, voice
“Smoke previously detected.”
NOTE: Alarm memory is only
retained for 24 hrs. Push button to
clear Alarm Memory.
Smoke Alarm Hush
TM
Mode
Red LED blinks every 2 sec.
(only on the initiating alarm)
After button push, voice
“Hush Mode Activated.”
Smoke alarm pattern stops.
If there is too much smoke to
allow Hush
TM
, voice “Too much
smoke, alarm cannot be hushed.”
(smoke alarm pattern continues)
This feature is to be used only when
a known alarm condition, such as
smoke from cooking, activates the
alarm. Push button during Hush
TM
to
clear Hush
TM
and perform a test.
Initiating Alarm
(multiple alarms in an
interconnected system)
Red LED blinks in time with
alarm pattern indicating that
this is the unit initiating the
alarm in an interconnected,
multiple alarm, system.
NOTE: It is possible for more
than one unit to detect a haz-
ard and become an initiating
alarm unit (Red LED blinking).
Unit in smoke alarm mode.