Kinetico Powerline PRO Specifications

General IconGeneral
BrandKinetico
ModelPowerline PRO
CategoryWater Dispenser
LanguageEnglish

Summary

Product Overview

Mechanical Timered Valve

System control regenerates softener on a given day of week using a 12-day timer.

Electrical Metered Valve

Regenerates based on actual water used, tracked by an integrated system meter.

System Cycles

Backwash

Reverses water flow through mineral tank to flush particles to drain.

Brine & Rinse

Uses brine to remove hardness ions and rinses excess brine.

Rapid Rinse

Settles and recompacts resin bed by directing water flow downward.

Brine Refill

Adds fresh water to salt compartment for new brine solution.

Service

Normal operation cycle where hard water exchanges ions for soft water.

System Maintenance and Install Guidelines

Adding Salt

Ensure salt level in brine tank is above water line; do not use rock salt.

Water Pressure Requirements

Inlet water pressure range of 20-125 psi is required for effective operation.

Electrical Facilities

Requires uninterrupted AC supply; voltage must be compatible; 9-Volt battery backup recommended.

Existing Plumbing

Plumbing should be free from buildup; replace piping or install iron filter if needed.

By-pass Valves

Install if unit is not equipped; turn to bypass position if leaking.

Set-up Procedures

System Adjustments Using Push Button/Display Interface

Guide for setting time of day, AM/PM, and compensated hardness.

System Adjustments Using Smart Phone/Tablet Interface

Instructions for using Bluetooth interface with compatible smart devices.

Normal Operation

Battery Backup

Maintains time of day during power failures; display turns off to conserve power.

Starting Extra Regeneration Cycle

Initiate delayed or immediate extra regeneration cycles manually.

Regeneration Cycle Steps

Details common cycle step times: Backwash, Brine Draw, Rapid Rinse, Brine Refill.

Troubleshooting Guides

Softener Fails to Regenerate Automatically

Addresses issues with power supply, meter, or control valve programming.

Regeneration at Wrong Time

Troubleshoots issues related to time of day, regeneration time, and hardness settings.

Loss of Capacity

Covers causes like resin fouling, internal valve leaks, and resin age.

Poor Water Quality

Investigates issues like by-pass valve, channeling, high salt setting, or brine tank water.

High Salt Usage

Addresses constant flow or regenerating too frequently.

Loss of Water Pressure

Troubleshoots scaling, fouling of inlet pipe, or improper backwash settings.

Excessive Water in Brine Tank and/or Salty Water to Service

Diagnoses problems with drain line, brine valve, injector screen, or low inlet pressure.

Softener Fails to Use Salt

Covers issues like no water in brine tank or low water pressure.

Continuous Flow To Drain

Addresses problems with jammed valves or motors.

Error Codes

Lists error messages indicating potential control valve issues and required service.