1A - WARNINGS
1B - AVAILABLE VERSION
1 - GENERAL DESCRIPTION
Unfulfilment of the below listed direction will release the KING gates srl, from any responsibility for damage caused to people
or things.
-Do not modify the product in any part.
-To optimize the functioning of the automation, King gates accessories only
.-Installing, testing and first functioning have to observe the laws in force.
-The gear-motor doesn’t require any maintenance because provided with a permament lubrification system.
-Disposal of waste material has to observe local regulations.
A - Gear-motor
B - Control unit
C - Flash-light with antenna
D - Photocell in closing
E - Photocell in opening
F - Key selector
G - Warning sign
H - Stop locks
Code
Couper 24
AVAILABLE VERSION
Motor
24 Vdc
(1)
Mechanical
stop
Wing max
dimensions
2m - 250 kg
Fixing kit
2A - TYPICAL SYSTEM
C
G
A
H
B
A
H
E2
H
E1
D2
F
D1
F
C
0,5mm2 (dist max 20m)
0,5mm2 (dist max 20m)
0,5mm2 (dist max 50m)
0,5mm2 (dist max 50m)
Ant + -
E2
E1
Tx Rx
+ + NC - PHO2 - -
B
A
2B - TYPICAL CONNECTION AND CABLE SECTION
2 - TYPICAL SYSTEM
RG58 (dist max 5m)
0,5mm2 (dist max 30m)
0,5mm2 (dist max 30m)
0,5mm2 (dist max 30m)
D2
D1
Tx Rx
+ + NC - PHO2 - -
0,5mm2 (dist max 30m)
0,5mm2 (dist max 30m)
0,5mm2 (dist max 30m)
L
N
1,5mm2 (dist max 20m)
1,5mm2 (dist max 20m)
A
min 3X0,75
min 3X0,75
COUPER 24 – TECHNICAL DATA
(Vac)
230
(Vac/Vdc)
24
(W)
80
(m/sec)
0,013 ÷ 0,016
(mm)
360
(IP)
44
(kg)
6
(m)
2
(kg)
250
(%)
50
(mm)
100x104x780
(°C)
-20 ÷ +50
Power supply
Gear motor
Power
Speed
Travel
Work cycle
Working temperature
Max length of the gate
Max weight of the gate
Protection level
Weight
Dimensions