DESCRIPTION OF PELLET UNIT
Cleaning window
Boiler control
Internal circulator
Boiler
Hot water exchanger
Fuel screw conveyor
Burner
Ash cleaning drawer
Fuel tank cap
Fuel tank
DESCRIPTION
Conditions to be checked before installation
Install the pellet unit in a place where abduction of the exhaust gas and the noise of the unit will not cause
any inconvenience to the users of the equipment and the residents of the surrounding area.
Do not install the unit near any place where there is frequent access to people such as stairs or emergency
exit.
Provide adequate space for the operation of the unit, its inspection and repair (1 m or more from the top, left
and right side).
Do not install the unit in an area that does not have enough ventilation. The lack of oxygen causes
incomplete combustion.
Never install the unit outside in the open space exposed to the weather conditions, it will create problems in
its operation and its lifetime.
Installing the unit directly on the floor the base of the unit can corrode reducing its lifetime.
Place the unit on surfaces of uninflammable material, 50 mm above the floor like concrete blocks.
The installation of the unit should be executed by a qualified technician according to instructions provided by
the user manual.
Install a fire extinguisher in the boiler room.
Do not store wood and do not place the unit near combustible materials. Keep the surroundings clean.
Contact customer service when the unit needs repair.