Document No.:KE-4010-11 Page: 8/58
11. AirConsumption
Airconsumptionmeansthevolume(Q)oftheairreleasedtotheatmospherefromanactuatoroperating[n]
timesforwardandbackwardperhourasconvertedtotheaveragevolumeperminute. Decidethecapacityof
anaircompressorusingtheresultofthefollowingcalculation. Werecommendtouseanairreservoirofan
adequatesizetoconstantlyoperateanactuatoratthepresettime.
◆ AirconsumptionofTypeFAdoubleactionactuators:
Q=(V1+V2)(P+0.1013)/0.1013 x n/60 [
L/min.(ANR)]
◆ AirconsumptionofTypeFASspringreturnactuators:
Q=V3(P+0.1013)/0.1013 x n/60 [
L/min.(ANR)]
V1,V2andV3: Volumeofactuatorhousing [
L]
RefertoTable2andtheillustrationshownbelow.
P:Airoperationpressure[MPaG]
n: Numberofoperationcyclesperhour

Table2Volumeofactuatorhousing[
L]
Actuator
V
1
V
2
Actuator
V
3
FA−1
FA−2
FA−3
FA−4
FA−5
FA−6
0.15
0.31
0.61
1.29
2.29
5.27
0.15
0.31
0.61
1.29
2.29
5.27
FAS−1
FAS−2
FAS−3
FAS−4
FAS−5
FAS−6
0.15
0.31
0.61
1.29
2.29
5.27