Document No.:KE-4010-11 Page: 19/58
Dontforgettoremovethespannerorthewrenchusedformanualoperationafterthe
actuatorisresetforautomatedoperation. Otherwisethespannerorthewrenchmay
jumpoutandinjurenearbypersonnelanddamagenearbyproperties.
Ensure to equalize the housing pressure with the atmospheric level before manual
operation. Leavingtheresidualairpressureinthehousingistoohazardoustonearby
personnelandproperties.
19.3ManualoperationofenergizedTypeFAdoubleactionactuators
(1) All KITZ optional solenoid valves are provided with a manual switch. Choose any one of the following
solenoidvalvesformanualoperationoftheactuatorsbeingenergized.
① KOGANEIModelA180
Keeppressingaswitchwiththetipofascrewdriverformanualoperation.Removalofthescrewdriver
returnstheactuatortotheoriginalautomatedoperationmode.
② CKDModel4F310
Rotateaknobformanualoperation.
③ KANEKOModelMK15G
Pulloutaswitchformanualoperation.
④ ASCOSCXD551
Setthepositionofamanualoperationthread,withascrewdriver,toPosition[O]oftheindicatorfor
manualoperation. SetittoPosition[1]toenergizetheactuatorforautomatedoperationmode.
20. InspectionandMaintenanceofActuatorsandActuatedValves
20.1 Both actuators and actuated valves are designed for lubrication-free operation, and maintenance or
replacementofpartsandcomponentsisnotusuallyneeded,exceptconsumablesealingmaterials.
20.2Ifagingorhighlyfrequentusehascausedmalfunctionorfailureofactuatorsoractuatedvalves,useKITZ
genuinepartsforreplacement.
20.3Ifactuatorsareequippedwithairfilter-regulators,periodicallycleantheboreofdraincockstoremoveall
internalresidues.
20.4 Replace sealing materials such as O-rings and gaskets, if any leakage is detected through sealed
connectionsofactuatorsandaccessories.