Document No.:KE-4010-11 Page: 17/58
17. OptionalDesignSpecifications
The following design specifications can be optionally accommodated for KITZ F Series pneumatic valve
actuators. Fordetails,refertoAppendixofthismanual.
OptionalDesignSpecifications
Options
Designspecifications
Lowtemperature -40℃(-40°F) to +60℃(+140°F) ambient
Service
temperatures
Hightemperature -20℃(-4°F) to +100℃(+212°F) ambient
5K
for0.5MPaoperatingpressure
Spring
cartridges
3K
for0.3MPaoperatingpressure
AIR-FAIL-OPENmode
toopenvalveswithspringrepulsingforce
Adjustmentofvalveopeningrange tostopvalvetravelatadesiredposition
Doubleaction
withmanuallever
Manualoperation
Springreturn
withmanuallever
NPTthreading forairinlet/outletports
18. Automatic OperationofActuators
18.1KITZFSeriespneumaticvalveactuatorsareoperatedwiththestandardairpressureof0.4MPa,however,
canbesetforoperationwithminimum0.3MPaandmaximum0.7MPaairpressure. Actuatorsequippedwith
airfilter-regulatorsaresetforoperationwith0.4MPa.
18.2Compressedinstrumentationair(ornitrogengas)isthestandardoperationmedium. Useofairfilters
andair dryers arerecommendedtokeepthe airinthe housing dry andcleanfor trouble-free operationof
actuators.
18.3Checkthefollowingpointsduringpilotoperationofyouractuators.
(1) In case of spring return type actuators, check a cap on the breathing port is removed before running
automatedoperation.
(2)Checktrouble-freefunctionoftheactuatorbymanuallyorautomaticallyoperatingitafewcycles.
(3)Checkairleakagefromtheairtubingthroughatravelfromacompressortotheactuator.Iftheoperation
modeoftheequippedsolenoidvalveischangedfromAIR-TO-OPENtoAIR-TO-CLOSEorviceversa,the
gasketconnectionbetweenthesolenoidvalveanditsadaptormustbealsocheckedforairleakage.
(4)Checkifasolenoidvalveisprovidedwithyourrequiredspecifications.