Document No.:KE-4010-11 Page: 9/58
Therequiredcapacityofanaircompressordependsontheavailabilityandthevolume
ofanairreservoir,thenumberofhourlyoperations,thetimerequiredforvalvestroke
andwhethertheaircompressorisusedexclusivelyorotherwisefortheactuator.
Todecidethepracticalcapacityofaircompressorsandreservoirs,addingsomeextra
30%tothecalculatedairconsumptionvolumeisrecommendedtoabsorbpossibleloss
ofaircausedduringatravelthroughairtubingandaccessories.
Useanair-filtertocontinuallysupplyclean,dryairtoanactuator.
Useplastictapesfortightlysealingpipingconnection,ensuringthattapeendsdonot
enterintothetubeboreandblocktheport.
Alsoensurethatthereisnoleakageofairthroughalltubingconnections.Insufficient
supplyofairpressurecausesmalfunctionorfailureofanactuator.
Appropriatelydesignthetotallengthofairtubing. Toolongairtubingcausespressure
loss or insufficient flow rate of the air, and results in malfunction or failure of an
actuator.
12. HandlingandStorageofActuatorsandActuatedValves
12.1Storeactuatorsandvalvesincool,dry,corrosion-freeenvironmenttokeepthemrust-freeandprevent
theirmalfunction,althoughsurfacesareappropriatelyfinishedforprimaryprotection.
12.2 Actuators and actuated valves are provided with dust protectors and packed individually for damage
prevention. Dontunpackthemanddontremoveprotectorsuntilyouarereadytoinstallthemonpipes.
12.3 Overloading actuators and valves mustbe prevented.Dontfall themon the ground. Dont place any
otherobjectsonthem. Dontsteponthem.
Actuatorsoractuatedvalvesareindividuallypackedandallopeningsandconnections
aresealedfordustprevention. Dontunpackthemanddontremoveprotectorsuntil
youarereadytoinstallthemonpipes.
Modification of actuators or actuated valves is forbidden, unless accepted by KITZ
Corporationortheauthorizedmodificationshopsinadvance.
Carefully handle actuators packed particularly in cardboard cases, since the cases
mighthavebecomeveryfragileduetomoistureandothercauses.
Care must be taken to handle actuators equipped with solenoid valves and other
accessoriesduringstorageortransportation.
Store actuatorsor actuatedvalves in cool, dry, corrosion-free environmentto keep
themrust-freeandpreventtheirmalfunctionorfailure.