Document No.:KE-4010-11 Page: 7/58
10. SupplyofAirOperationPressure
10.1 For the actuator factory-assembled with a solenoid valve, provide the air tubing between the air
compressorandthesolenoidvalve. AirinletsareRc1/4.
10.2 Use copper, coated copper or plastic tubes of an adequate diameter and wall thickness. Clean tube
borestoremoveallforeignresiduesandtightlysealallconnectionstoavoidleakageofairduringatravelfrom
thecompressor.
10.3Ifyouwanttomountyourownsolenoidvalvesotherthanthosefactory-assembled,selectthefollowing
type. ForTypeFAactuators,4-waysolenoidvalvesareused. ForTypeFASactuators,3-wayor4-way
solenoidvalveswithplugupjustoneportareused.
10.4AirinletsareRc1/4. Use6mmorsmallertubes,andhexagonalfittingsof19mmandsmallerwidthofflat.
ContactKITZCorporationfortechnicaladvice,ifyouwanttouselargertubesforfasteroperationofactuators.
10.5 Keep the air always free from dust and moisture ( -15℃ or lower dew point under the atmospheric
pressure),usingair-filtersandair-dryers.
10.6Choosethecapacitiesofyourownaccessoriesandthesizesofauxiliaryairtubing,inconsiderationof
possiblelossofairpressureduringatravelfromthecompressor.
10.7Theexactvolume(Q)ofairsupplyrequiredperminuteforactuatorsmustbeknownbeforetheairtubing
installationsothattheprovidedoperationpressuremaybesufficienttoproperlydriveactuatorsandvalves.
Calculateyourairsupplyrequirementwiththefollowingequation.
10.8Therequiredairpressuremustbekeptconstantattheairinletofanactuator. Insufficientairsupply
causesintermittentpistondriveandresultsinmalfunctionofactuators.
Q=V(P+0.1013)/0.1013 x 60/t [
L/min.(ANR)]
V:Volumeofactuatorhousing[
L] (V1orV2inSection10)
P:Airoperationpressure[MPaG]
t:
Timerequiredperstroke[second]under0.4MPaoperationpressure,whereno
valvenoraccessoryisprovided. (RefertoTable1)
ANR: Airsupplyvolumeunderthestandardconditionof20℃ (68°F),
760mmHgabsolutepressureand65%relativehumidity
Designofsolenoidvalvemountingpad
(airinlet/outletports)
Actuatortype Time[sec]
FA/FAS-1
FA/FAS-2
FA/FAS-3
FA/FAS-4
FA/FAS-5
FA/FAS-6
0.2
0.3
0.4
0.6
1.0
2.0
Table1.
Time[t]requiredperstroke
under0.4MPaoperation