Dwg Name: CL210-1390114ART
Dwg No: 1390114
ECO No: 20550 Rev: D
Pkg Dwg Ref: 1290186
Color Reference: N/A
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
200.0mV 0.1mV ±(2.5% + 10 digits)
2.000V 1mV
±(2.0% + 5 digits)
20.00V 10mV
200.0V 100mV
600V 1V
DC Voltage
(V DC)
200.0mV 0.1mV ±(1.0% + 8 digits)
2.000V 1mV
±(1.0% + 3 digits)
20.00V 10mV
200.0V 100mV
600V 1V
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
2.000A 1mA ±(2.5% + 30 digits)
20.00A 10mA
±(2.0% + 10 digits)200.0A 100mA
400A 1A
Frequency Range: 50 to 60Hz
Resistance
200.0Ω 0.1Ω ±(1.2% + 5 digits)
2.000KΩ
±(1.2% + 3 digits)
20.00kΩ 10Ω
200.0kΩ 100Ω
2.000MΩ 1kΩ
20.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
-4to 1832°F
1
°F
≤0°F ±(2.8% + 12 digits)
>0°F ±(2.8% + 6 digits)
-4to 1000°C
1
°C ±(2.8% + 6 digits)
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Auto Power off: After ~15 minutes of inactivity
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3 ½ digit, 2000 Count LCD
CL210-1390114ART.indd 3 10/1/2015 3:42:23 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL210 and is the answer not in the manual?

Klein Tools CL210 Specifications

General IconGeneral
BrandKlein Tools
ModelCL210
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals