OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 750V AC RMS
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-5/6 digit, 6000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
60.00nF 0.010nF ±(4% + 25 digits)
600.0nF 0.100nF
±(4% + 8 digits)
6.000μF 0.001μF
60.00μF 0.010μF
600.0μF 0.100μF
6.000mF 0.001mF ±(5% + 9 digits)
Maximum Input: 750V AC RMS or 600V DC
Temperature
°F
-328° to 54°F
1
°F
±(1.5% + 7 digits)
55° to 2462°F
±(1.2% + 6 digits)
Temperature
°C
-200° to 12°C
1
°C
±(1.5% + 4 digits)
13° to 1350°C
±(1.2% + 3 digits)
Maximum Input: 750V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
(≤10kHz)
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 750V AC RMS or 600V DC