ELECTRICAL SPECIFICATIONS
Diode Test: 1.5 mA max, open circuit voltage 3.0V DC
Continuity Check:
Audible signal <50Ω
Sampling Frequency:
3 samples per second
Overload:
"OL" indicated on display
, overload protection
600V RMS in all settings
Polarity:
"-" on display indicates negative polarity
Display:
3 ¾ digit, 4000 Count LCD
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
Before each use verify meter operation by measuring a known
voltage or current.
Never use the meter on a circuit with voltages that exceed the
categor
y based rating of this meter.
Do not use the meter during electrical storms or in wet weather
.
Do not use the meter or test leads if they appear to be damaged.
Use only with CA
T III or CAT IV rated test leads.
Ensure meter leads are fully seated, and keep fingers away
from the metal probe contacts when making measurements.
Do not open the meter to replace batteries while the probes
are connected.
Use caution when working with voltages above 25V AC RMS
or 60V DC. Such voltages pose a shock hazard.
To avoid false readings that can lead to electrical shock,
replace batteries when a low batter
y indicator appears.
Do not attempt to measure resistance or continuity on a live
cir
cuit.
Always adhere to local and national safety codes. Use personal
protective equipment to prevent shock and ar
c blast injur
y
where hazardous live conductors are exposed.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM400 and is the answer not in the manual?

Klein Tools MM400 Specifications

General IconGeneral
Product typeDigital multimeter
DC voltage range600 - 600 V
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Resistance resolution40 Ω
Resolution (frequency)50 Hz
Temperature measurement range-18 - 538 °C
Display digits4000 digits
Battery typeAAA
Power sourceBattery
Number of batteries supported2
Weight and Dimensions IconWeight and Dimensions
Depth152 mm
Width80 mm
Height45 mm
Weight231 g

Related product manuals