EasyManua.ls Logo

KNF N035.1.2 AN.18 - User Manual

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
KNF 121228-121398 04/14
Translation of original Operating Instructions, english Keep for future use!
Operating Instructions
Read and observe these Operating Instructions!
Diaphragm Vacuum Pumps and Compressors
N035 AN.18
N035 AT.18
N035 AV.18
N035.1.2 AN.18
N035.1.2 AT.18
N035.1.2 AV.18
N035.3 AN.18
N035.3 AT.18
N035.3 AV.18
KNF Neuberger GmbH
Alter Weg 3
79112 Freiburg
Germany
Phone +49-(0)7664 / 5909-0
Fax +49-(0)7664 / 5909-99
E-Mail: info@knf.de
www.knf.de
Contents Page
1. About this document ................................................................. 3
2. Use ............................................................................................ 4
3. Safety ........................................................................................ 5
4. Technical Data .......................................................................... 7
5. Design and Function ............................................................... 11
6. Installation and connection ...................................................... 13
7. Operation ................................................................................. 14
8. Servicing .................................................................................. 16
9. Troubleshooting ....................................................................... 20
10. Spare parts and accessories ................................................... 22
11. Returns .................................................................................... 23
12. Health and safety clearance and decontamination form ......... 24

Questions and Answers

  • G
    garrettmayerAug 8, 2025
    What to do if KNF N035.1.2 AN.18 does not transfer?
    • V
      Vanessa PowersAug 8, 2025
      If your KNF Water Pump isn't transferring, there are several potential causes: * **No voltage:** Check the room fuse and switch it on if necessary. * **Overheating:** Disconnect the pump and allow it to cool down. Identify and resolve the cause of overheating. * **Blockages:** Inspect connections and lines for any blockages and remove them. * **External valve/filter issues:** Check external valves and filters. * **Condensate in pump head:** Detach the condensate source and flush the pump. * **Worn valves:** Replace the diaphragm and reed valves (valve plate).
  • C
    Christopher HernandezAug 25, 2025
    What to do if KNF Water Pump is on but not running and the switch is not lit?
    • A
      Alexandria WalterAug 25, 2025
      If your KNF Water Pump is switched on but not running, and the on/off switch isn't lit, it could be due to these reasons: * **Not connected to power:** Connect the pump to the mains power. * **No voltage:** Check the room fuse and switch it on if necessary.
  • N
    Nathan CoxAug 31, 2025
    What to do if KNF N035.1.2 AN.18 Water Pump is on but not running and the switch is lit?
    • J
      James MartinAug 31, 2025
      If your KNF Water Pump is switched on but not running, and the on/off switch is lit, it's likely due to the thermal switch opening because of overheating. To resolve this, remove the pump’s mains plug from the socket, allow the pump to cool down, and then identify and eliminate the cause of the overheating.
  • V
    Vanessa MillerNov 15, 2025
    Why is the flow rate, pressure, or vacuum too low on my KNF N035.1.2 AN.18 Water Pump?
    • B
      brent38Nov 16, 2025
      If the flow rate, pressure, or vacuum is too low on your KNF Water Pump, consider these possible causes: * **Condensate in pump head:** Detach the condensate source from the pump and flush the pump. * **Pressure Imbalance:** Change the pressure conditions if there's gauge pressure on the pressure side along with vacuum or excessive pressure on the suction side. * **Insufficient cross-section:** Disconnect the pump to check output values. If needed, eliminate throttling and use larger lines or connection parts. * **Leaks:** Ensure tubes are correctly placed on hose nozzles, replace leaky tubes, and eliminate any leaks. * **Jammed connections:** Inspect connections and lines, removing any obstructions. * **Soiled Head:** Clean the head components. * **Worn valves:** Replace th...

Summary

1. About this document

1.1. Using the Operating Instructions

Guidance on how to effectively use and follow the operating instructions for the pump.

1.2. Symbols and Markings

Explanation of warning symbols, signal words, and other important markings used in the manual.

2. Use

2.1. Proper use

Details the intended application and correct usage of the diaphragm vacuum pumps and compressors.

2.2. Improper use

Outlines prohibited uses and situations to avoid for safe and effective operation.

4. Technical Data

5. Design and Function

6. Installation and connection

6.1. Installation

Procedures and considerations for physically installing the pump at the operational location.

6.2. Connection

Steps for connecting pneumatic lines, accessories, and electrical power to the pump.

7. Operation

7.1. Preparing for Start-up

Checks and requirements to ensure the pump is ready for operation before switching it on.

7.2. Starting

Instructions and safety warnings for safely starting and operating the pump.

7.3. Switching pump on and off

Detailed steps for safely switching the pump on and off, including thermal switch behavior.

8. Servicing

8.1. Servicing Schedule

Recommended intervals and tasks for routine inspection and maintenance of the pump.

8.2. Cleaning

Instructions for cleaning the pump components and flushing the pump.

8.3. Changing Diaphragm and Valves

Step-by-step guide for replacing worn diaphragms and reed valves.

9. Troubleshooting

10. Spare parts and accessories

11. Returns

12. Health and safety clearance and decontamination form

KNF N035.1.2 AN.18 Specifications

General IconGeneral
Voltage12 V
Power SupplyDC
Motor TypeDC motor
Liquid temperature range5°C to 40°C
Materials in contact with the liquidEPDM
SeriesN 035 series

Related product manuals