KNF Neuberger BA121556-121559 NMP830_850-EN 0221.doc
Translation of original Operating and Installation Instructions, English Keep for future use
Operating and Installation Instructions
Micro Diaphragm Gas Pumps
Type range:
NMP 830 KPDC
NMP 830 KPDC-B
NMP 830 KNDC
NMP 830 KNDC-B
NMP 830 KNE
NMP 830 KVDC
NMP 830 KVDC-B
NMP 830 KVE
NMP 830 KTDC
NMP 830 KTDC-B
NMP 830 KTE
NMP 850 KPDC
NMP 850 KPDC-B
NMP 850.1.2 KPDC-B
NMP 850 KTDC
NMP 850 KTDC-B
NMP 850.1.2 KTDC-B
You have selected a high-quality KNF product; the following tips will help you operate it safely, and
reliably over a long period of time. Carefully study the Operating and Installation Instructions before
using the pumps and observe at all times the relevant instructions to avoid dangerous situations. The
manual was produced for the serial pumps stated above. With customer-specified projects (pump
types starting with “PJM“ or “PMM“) there could be differences in detail. For customer-specified pro-
jects please therefore take into account any agreed technical specifications, as well as these instruc-
tions.
Contents Page
1. About this document ................................................................. 2
2. Use ........................................................................................... 3
3. Safety ....................................................................................... 4
4. Technical Data.......................................................................... 6
5. Design and function ................................................................ 10
6. Installation and connection ..................................................... 11
7. Operation ................................................................................ 15
8. Servicing ................................................................................. 16
9. Troubleshooting ...................................................................... 20
10. Returns ................................................................................... 22
KNF Micro AG
Zelglimatte 1b
CH-6260 Reiden
Switzerland
Phone 0041(0)62 787 88 88
E-mail: info.micro@knf.com
www.knf.com

Questions and Answers

  • Y
    ygarciaAug 9, 2025
    Why is the flow rate low on my KNF NMP 830 KPDC?
    • C
      Cheryl LewisAug 9, 2025
      If your KNF Water Pump's flow rate, pressure, or vacuum is too low, several factors could be responsible. Condensation in the pump head can be resolved by installing the pump at the system's highest point. Pressure imbalances can be addressed by changing the pressure conditions. Insufficient cross-sections in pneumatic lines or connections require disconnecting the pump to assess output, eliminating throttling, and using larger cross-section lines or parts if necessary. Leaks should be eliminated, and any blockages in connections or lines need to be cleared. Soiled head parts should be cleaned. Finally, worn diaphragms or valve plates should be replaced.
  • A
    Alicia LopezAug 25, 2025
    What to do if my KNF Water Pump does not transfer water?
    • S
      Shirley StarkAug 25, 2025
      If your KNF Water Pump isn't transferring fluid, start by checking for blockages in the connections and lines and remove any obstructions. Ensure that external valves are open and filters are not clogged. If condensate has collected in the pump head, install the pump at the highest point in the system. If the diaphragm or valve plates are worn, consider replacing the pump.