EasyManua.ls Logo

KNF N035.3 AN.18 - User Manual

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
KNF 121228-121398 04/14
Translation of original Operating Instructions, english Keep for future use!
Operating Instructions
Read and observe these Operating Instructions!
Diaphragm Vacuum Pumps and Compressors
N035 AN.18
N035 AT.18
N035 AV.18
N035.1.2 AN.18
N035.1.2 AT.18
N035.1.2 AV.18
N035.3 AN.18
N035.3 AT.18
N035.3 AV.18
KNF Neuberger GmbH
Alter Weg 3
79112 Freiburg
Germany
Phone +49-(0)7664 / 5909-0
Fax +49-(0)7664 / 5909-99
E-Mail: info@knf.de
www.knf.de
Contents Page
1. About this document ................................................................. 3
2. Use ............................................................................................ 4
3. Safety ........................................................................................ 5
4. Technical Data .......................................................................... 7
5. Design and Function ............................................................... 11
6. Installation and connection ...................................................... 13
7. Operation ................................................................................. 14
8. Servicing .................................................................................. 16
9. Troubleshooting ....................................................................... 20
10. Spare parts and accessories ................................................... 22
11. Returns .................................................................................... 23
12. Health and safety clearance and decontamination form ......... 24

Questions and Answers

  • A
    allenmargaretAug 8, 2025
    What to do if KNF N035.3 AN.18 does not transfer?
    • M
      Mary OrtizAug 9, 2025
      If your KNF Water Pump isn't transferring, there are several potential causes: * **No voltage:** Check the room fuse and switch it on if necessary. * **Overheating:** Disconnect the pump and allow it to cool down. Identify and resolve the cause of overheating. * **Blockages:** Inspect connections and lines for any blockages and remove them. * **External valve/filter issues:** Check external valves and filters. * **Condensate in pump head:** Detach the condensate source and flush the pump. * **Worn valves:** Replace the diaphragm and reed valves (valve plate).
  • M
    Martha WhiteAug 23, 2025
    What to do if KNF N035.3 AN.18 Water Pump is on but not running and the switch is not lit?
    • G
      grahamrachelAug 25, 2025
      If your KNF Water Pump is switched on but not running, and the on/off switch isn't lit, it could be due to these reasons: * **Not connected to power:** Connect the pump to the mains power. * **No voltage:** Check the room fuse and switch it on if necessary.
  • K
    kstewartAug 31, 2025
    What to do if KNF N035.3 AN.18 Water Pump is on but not running and the switch is lit?
    • D
      dsinghAug 31, 2025
      If your KNF Water Pump is switched on but not running, and the on/off switch is lit, it's likely due to the thermal switch opening because of overheating. To resolve this, remove the pump’s mains plug from the socket, allow the pump to cool down, and then identify and eliminate the cause of the overheating.
  • B
    bmunozNov 14, 2025
    Why is the flow rate, pressure, or vacuum too low on my KNF Water Pump?
    • T
      Tyler ArnoldNov 14, 2025
      If the flow rate, pressure, or vacuum is too low on your KNF Water Pump, consider these possible causes: * **Condensate in pump head:** Detach the condensate source from the pump and flush the pump. * **Pressure Imbalance:** Change the pressure conditions if there's gauge pressure on the pressure side along with vacuum or excessive pressure on the suction side. * **Insufficient cross-section:** Disconnect the pump to check output values. If needed, eliminate throttling and use larger lines or connection parts. * **Leaks:** Ensure tubes are correctly placed on hose nozzles, replace leaky tubes, and eliminate any leaks. * **Jammed connections:** Inspect connections and lines, removing any obstructions. * **Soiled Head:** Clean the head components. * **Worn valves:** Replace th...

Summary

About this document

Using the Operating Instructions

Guidance on how to read and follow the operating instructions for safe and effective use.

Symbols and Markings

Explanation of warning symbols, signal words, and other important icons used in the document.

Use

Proper use

Details on the intended applications and correct operational parameters for the diaphragm pumps.

Improper use

Lists prohibited uses and conditions that can lead to damage or hazards.

Safety

Technical Data

Design and Function

Installation and connection

Installation

Instructions for physically setting up the pump at the installation location.

Connection

Steps for connecting pneumatic lines, accessories, and power supply to the pump.

Operation

Preparing for Start-up

Pre-operation checks and requirements before switching the pump on.

Starting

Procedures and safety warnings for starting the pump, including pressure limits.

Switching pump on and off

Detailed steps for safely switching the pump on and off, including precautions for aggressive media.

Servicing

Servicing Schedule

Recommended intervals and actions for routine maintenance of pump components.

Cleaning

Procedures for cleaning the pump, including flushing and using solvents.

Changing Diaphragm and Valves

Step-by-step guide for replacing worn diaphragms and reed valves, including necessary parts and tools.

Troubleshooting

Spare parts and accessories

Returns

Health and safety clearance and decontamination form